About this measure
Differentiate grid tariffs by time and capacity so that grid charges signal the efficient use of the grid itself. This is a signal distinct from and complementary to the energy price: where energy tariffs reflect the cost of producing power at a given time, grid tariffs reflect the cost of moving it through a constrained grid. Differentiated charges encourage consumers and assets to use the grid when there is spare capacity and to moderate demand when it is stressed, allowing the deferment of reinforcement. The starting point requires no smart metering: capacity-based charges, recovering grid costs against the capacity a user draws rather than the volume consumed, can be introduced on existing metering, and they also address the cost shift that volumetric charging creates as distributed generation spreads, where self-consuming prosumers contribute progressively less towards a grid they still depend on for backup and export. Varying grid charges by time is the evolution, dependent on the smart metering in recommendation 5.2, as it can strengthen the price signal during periods of grid constraint. Ensure that reforms preserve overall cost recovery and avoid any undue burden on consumers who cannot respond.