How to Use
Glossary
This glossary explains the technical terms used across the toolkit, in plain language. The first section covers the terms used to describe the toolkit itself; the rest are listed alphabetically.
Terms used in the toolkit
Accelerators. Five features of the grid of the future that each bring together recommendations and measures from across the toolkit: a digital grid, a flexible grid, a distributed grid, an interoperable grid and a grid with aligned incentives. Pursuing the policies behind each accelerator as a coherent set speeds up progress.
Core and related measures and recommendations. A measure can support more than one recommendation. Each measure has a single “core recommendation”, the one for which it matters most, and may have several “related recommendations” that it also supports. A measure’s page lists both. A recommendation’s page lists both its “core measures”, i.e. the measures for which it is the core recommendation, and its “related measures”, i.e. the measures for which it is a related recommendation.
Domain. One of the four broad areas into which the toolkit groups the grid policy agenda: (1) “plan”, which covers the planning of grid and energy infrastructure; (2) “deploy”, which covers the construction of grid infrastructure and the connection of assets to the grid; (3) “operate”, which covers the operation of the grid and the coordination of the assets connected to it; and (4) “enable”, which covers the governance, capabilities and public support on which the other three domains depend.
Good practice. A real-world example of how a measure in the toolkit has been implemented.
Leading edge sets the floor. The principle that a power system’s stage is approximated by its most advanced driver among variable renewables, electrification and distributed energy resources.
Measure. A concrete policy or regulatory action through which a recommendation is put into practice. Each measure is assigned to one of the three stages of grid modernisation.
Objective. A policy goal within a domain, such as reforming grid planning or unlocking flexibility. The toolkit has nine objectives.
Recommendation. A specific area of reform under an objective that calls for policy action. Each objective has three recommendations, 27 in total.
Security, competitiveness and affordability. The three benefits the toolkit uses to describe what is at stake for each objective and recommendation.
Stages of grid modernisation. Three stages (foundation, acceleration, and transformation) that describe typical power system conditions and the policy priorities that go with them. They indicate when a measure typically becomes a priority.
A – Z
Adequacy. The ability of the power system to meet demand at all times, with sufficient generation, storage, demand response and grid capacity, taking account of planned and unplanned outages.
Aggregator. A party that pools many small resources, such as home batteries, EV chargers or flexible industrial loads, into a portfolio that can be offered and controlled as a single resource. Aggregation is the activity of doing so.
Alternatives to reinforcement. Options such as storage, demand flexibility, energy efficiency and operational measures that can meet a grid need instead of, or ahead of, building new grid infrastructure. Also called non-wire alternatives or non-wire solutions.
Ancillary services. See System services.
Anticipatory investment. Grid investment made ahead of confirmed demand or connection requests, where the future need is credible and well evidenced.
Balance responsible party. A market participant that is financially responsible for any difference between the electricity it has scheduled and the electricity its portfolio actually produces or consumes. See also Imbalance settlement.
Balancing. Keeping electricity supply and demand equal at every moment, which keeps system frequency within its permitted range.
Behind the meter. Located on the customer’s side of the electricity meter, as with rooftop solar, home batteries and EV chargers.
Black start. See System restoration.
Blended finance. The combination of public or concessional funds, guarantees or insurance with commercial capital to lower the cost and risk of an investment for private investors.
Bulk power system. The large power plants and the transmission grid that carries their output, together with the processes used to operate them.
Cable pooling. Connecting several generation or storage assets, such as a wind farm and a solar plant, through one shared grid connection whose capacity they manage together. It is a form of co-located connection.
Capacity-based tariff. A grid tariff that charges users according to the maximum power they draw or are entitled to draw, in addition to or in place of the energy they consume.
Congestion. A situation in which part of the grid cannot carry all the power that supply and demand would otherwise move through it. Congestion management covers the actions operators take to keep flows within safe limits.
Connection queue. The list of projects that have applied to connect to the grid and are waiting for assessment, a connection offer or the physical connection.
Curative congestion management. Allowing higher power flows before a fault because a fast, automatic remedy, such as an intertrip scheme or a grid-connected battery, acts after it. Conventional, preventive management limits flows in advance. Special protection or intertrip schemes are automatic systems that disconnect or reduce the output of designated grid-connected assets within milliseconds of a defined fault, so that the overload never occurs.
Curtailment. Reducing the output of a generator, or the import or export of another asset, below what it could deliver, usually because of grid constraints or surplus supply.
Demand response. Changes in when or how much electricity is consumed, in response to prices, incentives or instructions.
Digital grid model. A digital representation of the grid’s topology, assets and connected resources, used in planning, forecasting and operation. A digital twin is a version that is continuously updated with live data.
Dispatch. Instructing resources to produce or consume a specific amount of electricity at a specific time. Dispatchable resources, such as hydropower, gas plants and batteries, can be controlled in this way.
Distributed energy resources. Smaller-scale supply, storage and flexible demand, usually connected to the distribution grid and often behind the meter. Examples include rooftop solar, batteries, EVs and heat pumps.
Distribution grid. The lower-voltage part of the grid that delivers electricity to homes, businesses and most industrial users.
Distribution system operator (DSO). The organisation responsible for operating a distribution grid. An active DSO forecasts conditions on its grid, manages local constraints, and procures and dispatches local flexibility.
Dynamic line rating. Setting the capacity of a power line from actual and forecast conditions, such as temperature and wind, in place of fixed worst-case assumptions. The same principle can be applied to cables and transformers.
Dynamic operating envelope. Import and export limits for a grid connection that are recalculated close to real time according to grid conditions.
Dynamic pricing. Electricity prices that change frequently, often hourly or more often, to reflect conditions in the wholesale market or the power system.
Electrification. Switching energy uses in industry, transport and buildings from fossil fuels to electricity, for example through electric industrial processes, electric vehicles and heat pumps.
Energy community. A group of citizens, local businesses or local authorities that jointly own or operate energy assets or services, such as generation, storage or flexible demand.
Energy vector. A form in which energy is carried and delivered, such as electricity, gas, hydrogen or heat.
Fault ride-through. The ability of a generator, storage system or load to stay connected and keep operating through a short frequency or voltage disturbance, instead of disconnecting.
Firm connection. A connection right that guarantees the full requested capacity at all times, typically assessed against worst-case grid conditions.
Flexibility. The ability of a resource to change when or how much electricity it produces or consumes in response to the needs of the power system.
Flexible connection agreement. A connection offered faster or at lower cost in exchange for accepting curtailment or time-varying limits on import or export. Also called a non-firm connection.
Free, prior and informed consent. The right of indigenous peoples to give or withhold consent to projects affecting their lands, territories or resources, free of coercion, before decisions are taken and with full information. It is set out in the UN Declaration on the Rights of Indigenous Peoples.
Grid code. The technical rules that set out how generators, storage and demand must connect to and behave on the grid, for example during frequency or voltage disturbances.
Grid company. An organisation that owns, develops or operates a transmission or distribution grid. Depending on the system, a grid company may also be the system operator, and may be involved in generation and retail.
Grid-enhancing technologies. Technologies that increase the capacity or use of existing grid infrastructure, such as dynamic line ratings, power flow control devices and topology optimisation.
Grid-forming inverter. An inverter that can set frequency and voltage itself, providing the kind of stability support that synchronous generators have traditionally supplied. Grid-following inverters, in contrast, need a frequency and voltage reference set by the rest of the power system.
Hosting capacity. The amount of new generation or demand that can connect at a location without grid reinforcement or a loss of reliability. Hosting capacity maps publish this information.
Imbalance settlement. The process of calculating and charging for differences between scheduled and actual production or consumption. Its rules determine how the actions of an independent aggregator are accounted for against the customer’s supplier.
Independent system operator. An organisation that operates the power system without owning generation or retail businesses, and in some models without owning the grid assets themselves.
Inertia. The resistance to sudden changes in system frequency provided by the rotating mass of synchronous generators and motors. Inverters can provide a comparable fast response, known as synthetic inertia.
Intentional islanding. Operating a section of the grid on its own, disconnected from the wider system, to keep supplying customers during a disturbance.
Interconnector. A transmission link between the grids of two countries or regions.
Interoperability. The ability of devices and systems from different manufacturers to exchange information and act on common instructions.
Intertrip scheme. See Curative congestion management.
Inverter-based resource. A resource connected to the grid through power electronics, such as solar PV, wind turbines, batteries and EV chargers.
Large load. A single consumer with very high electricity demand, such as a data centre, an electrolyser, a large industrial site or a fleet-charging hub.
Locational signal. A price or charge that varies by location on the grid to reflect local constraints. Examples include nodal or zonal electricity pricing and locational grid charges.
Net metering and net billing. Two ways of paying prosumers for the electricity they export. Net metering credits exports at the full retail price; net billing credits them at a separate value, usually closer to their value to the system.
Non-wire alternatives. See Alternatives to reinforcement.
Observability. The extent to which operators can see conditions on their grid, such as power flows, voltages and equipment status, through metering, sensors and grid models.
Performance-based regulation. Revenue regulation that links a grid company’s earnings to the outcomes it delivers, such as reliability, connection speed or hosting capacity, in place of mainly the capital it invests. Also called output-based regulation.
Permitting. The administrative processes through which infrastructure projects obtain the approvals needed to be built, including environmental, planning and land-use consents.
Phased connection agreement. A connection agreement that releases grid capacity in stages, in line with a project’s expected growth.
Power purchase agreement (PPA). A long-term contract under which a buyer agrees to purchase electricity from a generator on agreed terms.
Prosumer. A consumer who also produces electricity, for example from rooftop solar, and may export some of it to the grid.
Reconductoring. Replacing the conductors on an existing power line with higher-capacity ones, increasing transfer capacity within the existing corridor.
Redispatch. Changing the planned output of generators or other resources to relieve grid congestion.
Regulated asset base. The value of a grid company’s investments on which the regulator allows it to earn a return.
Regulatory period. The period, typically several years, for which a regulator sets a grid company’s allowed revenues.
Regulatory sandbox. A supervised setting in which new technologies, tariffs or business models can be tested under temporary exemptions from certain rules, with defined consumer safeguards.
Reinforcement. Increasing grid capacity by building new infrastructure or upgrading existing physical assets.
Reliability. The ability of the power system to deliver electricity to users in the required quantity and quality.
Resilience. The ability of the power system to withstand and recover quickly from extreme events, such as storms, heatwaves, major equipment failures or cyberattacks.
Revenue stacking. Earning revenue from several services with the same asset, for example energy trading, balancing and grid services, provided the same capability is not sold twice.
Scenario-based planning. Planning against several distinct, plausible futures, so that investments are tested across a range of outcomes and do not depend on a single forecast.
Sector coupling. Linking the electricity system with other sectors and energy vectors, for example through electric heating, EV charging or the production of hydrogen from electricity.
Smart meter. An electricity meter that records consumption at short intervals and communicates the data remotely, enabling time-varying tariffs and visibility of the low-voltage grid.
Social licence. The ongoing acceptance and support of communities, grid users and the wider public for grid modernisation and the projects it involves.
Special protection scheme. See Curative congestion management.
Strategic corridors and zones. Areas designated in advance through spatial planning for grid infrastructure, or for renewables, storage and large loads, where projects can benefit from faster permitting and connection.
Strategic environmental assessment. An assessment of the environmental and social effects of a plan or programme, such as a grid development plan, carried out before individual projects are proposed.
Synchronous generator. A conventional generator, typically in a coal, gas, nuclear or hydropower plant, whose rotation is directly linked to the frequency of the power system.
System operator. The organisation responsible for operating a power system in real time. Transmission system operators run the bulk power system; distribution system operators run distribution grids.
System restoration. Restarting the power system after a widespread outage. Black start is the ability of a resource to start up without power from the wider grid and help restart it.
System services. Services other than the supply of energy that keep the power system stable, such as frequency response, voltage control, inertia, system strength and system restoration. Also called ancillary services.
System strength. The ability of the grid to maintain a stable voltage, particularly during and after faults. It is closely related to the level of fault current available.
Time-of-use tariff. A tariff with different prices for set periods of the day, such as peak and off-peak hours.
TOTEX-based regulation. A regulatory approach that treats capital and operating expenditure (CAPEX and OPEX) as a single cost base, so that grid companies have no financial preference between building infrastructure and using operational or flexibility-based solutions.
Transmission grid. The high-voltage part of the grid that carries electricity over long distances, from large power plants and between regions, to the distribution grids.
Transmission system operator (TSO). The organisation responsible for operating the transmission grid and, in most systems, for balancing the power system as a whole.
Unbundling. Separating grid operation, and in some cases grid ownership, from generation and retail activities, to avoid conflicts of interest.
Universal service obligation. A legal duty to give every consumer access to electricity supply of a defined minimum quality at reasonable prices.
Utilisation. How much of the grid’s capacity is actually used over time. Lines, cables and transformers are sized for the highest demand they may face, which often occurs for only a few hours a year, so for most of the time they carry well below what they could. Raising utilisation means making more use of this existing capacity, for example by shifting demand away from peak times or setting limits from actual conditions, which can defer or avoid the need for new grid infrastructure.
Variable renewable energy. Electricity from sources whose output varies with the weather, mainly solar and wind.
Virtual power plant. A portfolio of distributed energy resources, such as home batteries, EV chargers and heat pumps, that is coordinated to operate like a single power plant.
Wheeling. Transporting electricity over a grid owned by another party, for example from a generator to a buyer elsewhere on the grid, in exchange for a wheeling charge. It allows third parties to supply one another in systems with a single buyer or a vertically integrated utility.